CONTROL: FF-1094TC 120/240V 20A W/O BTNSimple and reliable four function control for any 2 pieces of equipment operated by 1 air button. Control distance up to 150′ depending on air button used.Replacement option for Len Gordon Co:910006-001 FF-1000TC910106-001 FF-1094TCA wiring diagram is provided inside the door of each unit. Diagrams detailing typical installations areshown below . THE POWER SUPPLY LlNE MUST BE CONNECTED TO THE BLACK ANDORANGE LINE PIGTAILS IN THE UNIT, AND THE POWER SUPPLY NEUTRAL MUST BECONNECTED TO THE WHITE NEUTRAL PIGTAILS IN THE UNIT! Certain models may havemore or fewer terminals than shown below.
Input Service Ratings:
- 120 VAC, 16 A, 1 HP, 60 Hz, 2 wire plus ground or –
- 240 VAC, 16 A, 2 HP, 60 Hz, 3 wire plus ground.
Output:
Maximum Output Ratings for Motor or Resistive Load Only-if two output circuits are used, thecombined total of both circuits shall not exceed the ratings noted below:
- 120 V, 16 FLA or; 240 V, 12 FLA and 240 V, 16 A Resistive.
Note:
Model FF-1094-the jumper across terminals 4 and 5 will operate the pump continuously. If this is notdesired, remove the jumper.
Installation
Caution: Use Copper Conductors only. Do not lubricate relays.