Skip to content
Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

FDXLHXA1500 Hayward H-Series H500FD Heater Heat Exchanger

$1,325.84

Item ID: 249664

Only 1 left in stock

Stock is Correct,
Even if you contact us to check.😀

New Product

SKU: FDXLHXA1500
Categories: ,

Heat Exchanger Assembly for Hayward H500FD Universal H-Series Low Nox Pool Heater FDXLHXA1500

Heat Exchanger Replacement Procedure

Heat Exchanger Service Parts Kits for Universal H-Series (Forced-Draft) HeatersIMPORTANT NOTES:REPLACEMENT PROCEDURE

  1. This kit is intended to be used only with Hayward Universal H-Series (forced-draft) gas heater models.These heaters may be identified by inspection of the heater rating plate (there should be an ‘FD’ in the model number), or by visual inspection of the heater in comparison to the diagrams in these instructions.
  2. This instruction sheet is intended for the following heaterservice parts kits:

FDXLHXA1250 Heat Exchanger Assembly, H250FDFDXLHXA1350 Heat Exchanger Assembly, H350FDFDXLHXA1400 Heat Exchanger Assembly, H400FDFDXLHXA1500 Heat Exchanger Assembly, H500FD

  1. Tum pump, main as valve, and heater power off.
  2. Remove drain plug and drain water out of heat exchanger.
  3. If necessary, disconnect header union fittings from pool/spa piping.
  4. Pull temperature limit switch wires through the grommet on the heater side panel. and disconnect limit switch wires from heater wire harness.
  5. Remove screws and remove both of the upper plastic heater side panels (see Figure 1 for screw locations, and Figure 2 for part location identification).
  6. Disconnect the 2 wires from the pressure switch. which is located on the inlet outlet header.
  7. Remove countersunk screws on heater top and  remove louvered exhaust panel on heater top (see Figure 2).
  8. Remove the heater top tlue cover by removing 3 screws on each side of the heater (see Figure 2).
  9. Remove screws and remove rain shield assembly (see Figure 2). Note that there are screws which hold therain shield assembly to the heat exchanger tube sheets, which also must be removed.
  10. Remove the front access panel and the control box cover (see Figure 2).
  11. Disconnect the temperature sensor plug from the circuit board located inside the control box.
  12. Pull the temperature sensor wires out of the control box and through the hole in the heater cabinet.
  13. Carefully lift the heat exchanger up and out of the heater cabinet.
  14. Before installing the new heat exchanger assembly, install the new adhesive-backed gaskets (included in this kit) onto both ,of the new heat exchanger tube sheets.
  15. Install the new heat exchanger assembly. Ensure the heat exchanger is properly oriented with the arrows on the tube sheet decal pointing up.CAUTION: Do not install heat exchanger upside down. Heat exchanger is labeled to indicate theproper orientation. The heat exchanger will be damaged if installed incorrectly.
  16. Remove the pressure switch from the old heat exchanger assembly and install on the new heat exchanger assembly. Apply pipe thread sealant to the pressure switch threads before assembly.
  17. Reverse the above steps to reassemble the heater.
  18. Activate water pump and check the system for leaks.